Series 2200
Batch Controller

The Data Industrial Series 2200 is a full featured, programmable batch controller. The flexibility of the 2200 allows it to be used in a wide variety of fluid batching and blending operations that require volumetric or time based measurement. The front panel mounted keypad is used for programming, setting the batch parameters and operation. The two control relays may be programmed to operate one or two stage batch operations. While one relay provides the primary batch function, the other may be used as a pre-warn, overrun signal or missing signal alarm. This second relay may also be used as a high or low flow alarm independent of the batching function. The START, STOP and RESET functions may also be duplicated for remote operation with the addition of an accessory card.

The two line X sixteen character alphanumeric display may be configured by the user to simultaneously display any two of the following: Flow Rate, Flow Total, Batch Status or Batch Count. The Batch Status mode may be programmed to count up or down, in either units of measure or percentage of batch. LED's are used to indicate batching relay status.

The Series 2200 will measure a single batch, a preset number of batches or will batch continuously with a programmable time delay between batches. The "End of Batch" signal from one unit may be used to start another. Enabling the Automatic Overrun Compensation feature allows the 2200 to adjust the end of the batch based on the overrun of the previous batch.

2200 Series w/ NEMA 4 Prewired
Hinged Metal Enclosure

The panel meter conforms to DIN Standard dimensions, 192 mm X 96 mm, for meter sizes and panel cut-outs. The 2200 is also available in NEMA 4 and NEMA 4X wall mount versions.

Like all Data Industrial flow monitors, the Series 2200 may be calibrated in the field. All Data Industrial flow sensors may be used along with any other digital pulse, sine wave or analog sensors, including non-linear and logarithmic signals. Up to twelve separate calibration points may be entered for linearization.

Programming is menu driven and all data is entered using five front panel mounted keys. A software lock allows the user to enter a password to prevent changing the totals, calibration or control settings. Programming flexibility is extended to the measurement units. The Series 2200 software contains nineteen rate of flow units and seven total flow units. There is also the provision for adding custom units for each.

Also written into the software is a self-diagnostic program that assists the operator in troubleshooting any problems.

The 2200 also provides a standard pulse output to interface with other batch controllers or external data collection devices that accept a pulse or dry contact closure. The resolution of the TTL compatible signal may be programmed from the front keypad.
All calibration information, units of measure, batch sizes and flow totals are stored in a non-volatile memory that does not require battery back-up for data storage.

A Model 2201 dual batch unit is available. This option allows two batch operations from a single unit. These can be volumetric batches from two flow streams using an optional input card, or time based. The dual batch version is equipped with four control relays.
The 2200 is expandable with a long list of options to custom tailor the unit for individual requirements.

These options include:

* Second batch channel- converts the 2200 to a dual batch device.
* Display backlighting- with variable contrast for low light situations.
* Power supplies- 12 VDC, 12-36 VDC, 24 VAC, 115 VAC or 230 VAC.
* Mechanical counters- built-in, non-resettable seven digit mechanical counters.
* Control relays- C Form mechanical relays, two additional available, independently programmed from the keypad by rate for alarms or pump control; or by total for counting and proportioning.
* Analog output- isolated 4-20 mA, 0 to 5 Volt or 0 to 10 Volt outputs, programmed from the keypad.
* Analog input- to accept inputs from other flow devices with analog outputs.
* RS232/485 port- allows two way serial communication with the 2200.

 

 